null Skip to main content

Cool Boss™ Fans

Filters Filters Filters
  • sale
    Cool Boss™ CB11HVLS 11.5' Industrial Overhead Fan Cool Boss™ CB11HVLS 11.5' Industrial Overhead Fan

    Cool Boss

    Cool Boss™ CB11HVLS 11.5' Industrial Overhead Fan

      Cool Boss™ CB11HVLS 11.5' Industrial Overhead Fan The CB-11HVLS has been designed from the ground-up to deliver ultimate energy-efficient solutions. Its fan blades are constructed of high-strength, fatigue resistant aluminum alloy, powder...

    $3,995.00
    $4,195.00
    Free Shipping
  • sale
    Cool Boss™ CB16HVLS 16.5'  Industrial Overhead Fan Cool Boss™ CB16HVLS 16.5'  Industrial Overhead Fan

    Cool Boss

    Cool Boss™ CB16HVLS 16.5' Industrial Overhead Fan

      Cool Boss™ CB16HVLS 16.5' Industrial Overhead Fan The CB-16HVLS provides year-round cooling solutions. Keeping you and your team in comfortable conditions ensures many benefits, like increasing overall productivity. Not only will your team...

    $4,795.00
    $5,095.00
    Free Shipping
  • sale
    Cool Boss™ CB20HVLS 20'  Industrial Overhead Fan Cool Boss™ CB20HVLS 20'  Industrial Overhead Fan

    Cool Boss

    Cool Boss™ CB20HVLS 20' Industrial Overhead Fan

      Cool Boss™ CB20HVLS 20' Industrial Overhead Fan Get a cool, comfortable airflow with the CB-20HVLS. Cool Boss HVLS fans are the perfect addition to large areas such as warehouses, factories, gyms, agricultural facilities, and more. Their...

    $5,995.00
    $6,395.00
    Free Shipping
  • sale
    Cool Boss™ CB24HVLS 24'  Industrial Overhead Fan Cool Boss™ CB24HVLS 24'  Industrial Overhead Fan

    Cool Boss

    Cool Boss™ CB24HVLS 24' Industrial Overhead Fan

    Cool Boss™ CB24HVLS 24' Industrial Overhead Fan The CB-24HVLS is more than up to the task of circulating massive amounts of air, and at a far lower cost when compared to traditional AC. It can also create far more comfortable environments for...

    $6,095.00
    $6,495.00
    Free Shipping

High-Volume, Low-Speed (HVLS) Industrial Ceiling Fans

Cool Boss™ HVLS fans are engineered for large-scale commercial and industrial environments where traditional cooling and air circulation methods prove impractical or cost-prohibitive. These massive overhead fans—ranging from 11.5 to 24 feet in diameter depending on the model—move tremendous volumes of air at low speeds, creating consistent airflow throughout warehouses, automotive service facilities, manufacturing plants, agricultural buildings, gyms, and other expansive spaces.

Unlike conventional high-speed fans that create localized gusts, HVLS fans generate a gentle, wide-reaching breeze that improves comfort without disturbing paperwork, parts, or workstations. The result is measurably better air circulation that helps regulate temperature, reduce humidity, and minimize hot or cold spots across the entire facility.

Year-Round Climate Control Benefits

Summer Cooling: HVLS fans create an evaporative cooling effect on skin, making occupants feel significantly cooler even without lowering the actual air temperature. When paired with evaporative coolers or existing HVAC systems, these fans distribute cooled air more effectively throughout the space, potentially reducing reliance on energy-intensive air conditioning.

Winter Destratification: Heated air naturally rises to the ceiling in large facilities, leaving floor-level work areas cold while wasting energy heating unused upper airspace. Operating an HVLS fan in reverse (or at low speed) gently pushes warm air back down to occupied zones, improving heating efficiency and maintaining more consistent temperatures throughout multi-level facilities without constantly running heating systems at maximum capacity.

Choosing the Right Fan Size for Your Space

Proper fan sizing depends on several factors including ceiling height, square footage, building layout, and intended use. Generally speaking:

  • Smaller diameter models (typically 11.5-16.5 feet) suit moderately sized spaces, lower ceilings, or areas requiring targeted air movement
  • Mid-range sizes (around 20 feet) effectively cover larger open floor plans with standard industrial ceiling heights
  • Larger diameter fans (up to 24 feet) maximize coverage in expansive facilities with high ceilings, minimizing the number of units needed

Professional assessment of your facility's dimensions, airflow requirements, and structural mounting capabilities helps ensure optimal fan placement and performance. Multiple smaller units may be more effective than a single large fan depending on building configuration and obstructions.

Construction and Engineering Features

Cool Boss HVLS fans feature robust construction designed for continuous operation in demanding environments. Key engineering elements typically include:

  • Aluminum Alloy Blades: High-strength, fatigue-resistant construction provides durability while keeping weight manageable for ceiling structures. Powder-coated finishes resist corrosion and simplify cleaning
  • Direct-Drive Magnet Motors: Eliminates reduction gearing and belts that require maintenance and eventual replacement, reducing long-term operating costs and potential failure points
  • Low-Noise Operation: Engineered for quiet performance that won't disrupt communication or concentration in work environments
  • Energy Efficiency: Moving large volumes of air while consuming relatively modest amounts of electricity compared to cooling entire facilities with HVAC systems alone

Installation and Structural Considerations

HVLS fans require secure mounting to properly rated structural supports capable of handling both the static weight and dynamic forces generated during operation. Installation typically involves:

  • Verifying ceiling structure can support the fan's weight and operational loads
  • Ensuring adequate clearance from ceilings, walls, equipment, lighting, and sprinkler systems
  • Meeting minimum mounting height requirements for safe blade clearance above floor level
  • Providing appropriate electrical service (voltage and amperage vary by model)
  • Following manufacturer installation guidelines and local building codes

Professional installation by qualified technicians familiar with HVLS systems ensures safe, code-compliant mounting and optimal performance. Improper installation can compromise safety and void manufacturer support.

Workplace Productivity and Safety Benefits

Maintaining comfortable working conditions directly impacts employee performance, accuracy, and safety. Effective air circulation helps:

  • Reduce heat stress and fatigue during physically demanding tasks
  • Improve focus and reduce errors caused by discomfort
  • Lower humidity levels that can affect materials, parts storage, and equipment
  • Minimize condensation issues on floors and surfaces
  • Enhance overall air quality by preventing stagnant air pockets

Integration with Existing Climate Systems

HVLS fans work most effectively as part of a comprehensive climate management strategy rather than standalone solutions. They can be integrated with:

  • Evaporative Coolers: Distributing cooled air from evaporative units across wider areas for enhanced cooling effect
  • HVAC Systems: Reducing air conditioning runtime by improving cool air distribution and creating wind-chill effects
  • Heating Systems: Recirculating warm air from ceiling level down to occupied zones during cold months
  • Ventilation Systems: Enhancing fresh air exchange in facilities with open doors or loading docks

Important: Specifications vary by model. Always check individual product listings and manufacturer documentation for exact details on fan diameter, motor specifications, mounting requirements, electrical needs, coverage area, and operational parameters before purchasing.

Cool Boss

Cool Boss Fans


 

Warning SignWARNING: These products can contains certain metals/chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

 
Review Your Cart Close Close
Your cart is empty